TO EMPTY AND CLEAN A SUMP COMPLETELY WHEN CHANGING FLUIDS:

Use the PFA-1002 to pump out, filter, and recover most of the coolant or cutting oil, then use the drum head VAC-55 + the existing shop wet/dry vacuum to vacuum the sludge & chips directly into the disposal drum without shoveling or scraping.

Results: Sump is emptied, Cutting oil or coolant is filtered and pumped
to a hold tank or back into the sump, Chips & Sludge are in a 55-gallon disposal drum___
No shoveling, scraping, or sludge transfer required!

See below: First, a description of the VAC-55,
Then, a description of the convenient three step process for cleaning sumps

VAC-55 DRUM HEAD

The VAC-55 converts your existing shop wet/dry vacuum into an efficient sump cleaning device, while protecting the shop vacuum from contamination by the sludge. The VAC–55 consists of a plastic head for a 55 gallon drum with two quick connect fittings for vacuum hoses, one hose to connect to the shop wet/dry vacuum cleaner, and the other a flexible hose with a wand to vacuum the sump. Simply place the light weight (10 lbs) VAC-55 on the drum which is to be used to dispose of the chips, connect the hose of the shop vacuum to the fitting provided, and vacuum the wet sludge/chips into the disposal drum, using the 6 foot flexible hose and 2 foot inlet wand to reach the corners of the sump. A short length of clear hose in the line to the wet/dry vac shows visually when the drum is full.

coolant oil sump filter cleaners
TO ORDER VAC-55 VACUUM DRUM HEAD:  
VAC-55 Vacuum Drum Head, with required tubing, inlet wand, & fittings $375.00

Note: Customer supplies drum (18 gauge minimum required) and wet/dry vacuum
SPECIAL OFFER!
Get one VAC-55 at 50% off when ordered with an order for one PFA-1002

SIMPLE 3-STEP METHOD TO EMPTY A SUMP AND RECLAIM THE FLUID

1) Pump out most of the fluid and filter suspended solids with PFA-1002

When changing the coolant or oil in the sump, the PFA–1002 pump/filter unit can pump out and filter most of the fluid and deliver the filtered coolant or oil to the feed tank or disposal drums. Solids collected in the bag filter can be emptied into the disposal drum. The PFA-1002 can pump out most of the liquid and suspended solids, but it leaves the settled thick sludge in the sump.

TO ORDER INLET WAND WITH U-FITTING:

 

#555-302 Inlet Wand with U-Fitting

$40.00

coolant oil sump filter cleaners

2) Vacuum chips/sludge into the disposal drum with VAC-55 and the shop vac

The chips & sludge remaining after pumping out with the PFA–1002 can be vacuumed directly into the disposal drum using the VAC–55 vacuum drum head and the existing shop wet/dry vacuum. The VAC-55 with the shop vacuum can rapidly clean essentially all the settled sludge from the sump and transfer it to the disposal drum, without any manual shoveling.

3) Using the PFA-1002, pump filtered fluid from the feed tank to refill the sump

Using the PFA-1002, pump filtered fluid from the feed tank or clean oil drum to recharge the sump. The self-priming pump on the PFA-1002 can pump from the feed tank using the hoses and fitting provided and deliver the filtered fluid under pressure to any location in the shop.

Results of the 3 Step Process:
1) Sump is completely emptied
2) Chips & sludge are in a 55-gallon disposal drum
3) Cutting oil or coolant is filtered and pumped to a hold tank or back into the sump.
No shoveling, scraping, or sludge transfer required!

SIMPLE METHOD TO CLEAN AND RECHARGE A GRINDER SUMP
To clean a sump with a particularly heavy load of solids, such as a grinder sump, pumping off liquid with suspended solids from the top of the sump with the PFA-1002 (as in step #1 above) may require inconveniently frequent filter bag cleanings or changes because of the solids load. A more convenient process, described below, is first to empty the sump completely into 55-gallon disposal drums with the VAC-55 and the shop vac, allow the solids to settle in the drums, and then pump off, filter, and recover the fluid using the PFA-1002.

1) Pull the contents of the sump into 55-gallon disposal drums using the VAC-55

Pull all the contents of the sump, including settled sludge, into 55-gallon disposal drums using the VAC-55 and shop wet/dry vacuum. Allow the solids in the drum to settle.

2) Using the PFA-1002, pump & filter the fluid and return it to the sump

After the sludge settles in the drum for several hours or overnight, recover and filter the liquid which has separated on top of the settled solids using the PFA-1002 and the inlet wand with the U-fitting. The U-fitting permits skimming the liquid without sinking the inlet wand into the sludge. The PFA-1002 can pump the filtered liquid back to the sump or to a clean liquid holding tank. The solids remain in the drum for disposal.